shower with heat pump water heater

Heat Pump Water Heater

Around 2005, air source heat pump water heater had been introduced to China manufacturers in Guangdong Province.

With the steadily developed markets around the world, the heat pump water heater is now widely installed and heating water for homes and commercial places with applications of sanitary hot water heating, pool heating and house heating.

Now the supply chain of components for the manufacturing of heat pump water heater is highly developed and makes the quality, the delivery and the price are all satisfied by customers.

Domestic models and commercial models of heat pump water heater are presented.

NAT Series - Domestic models

They have a built-in water pump for hot water circulation between the water heat exchanger inside the heat pump and an external water storage tank where hot water stored and ready for use.

The domestic heat pump water heater has a compact size and can be installed at a place without restriction.

hpwh_d_am5a
hpwh_d_am7a
Aseair Heat Pump Model: AWH-003PVC, AWH-005PVC, AWH-007PVC
Model AM3A AM5A AM7A
Heating Power * kW 3.5 5.0 7.0
Rated Input Power ** kW 0.87 1.24 1.75
COP W/W 4.02 4.03 4.0
Power Supply V/N~/Hz 220-240/1/50
Refrigerant / R410A
Applicable Ambient Temperature °C -7 to +43 -7 to +43 -7 to +43
Hot Water Production Volume * Ltrs/hour 75 108 150
Rated Water Outlet Temperature °C 55
Range of Water Outlet Temperature °C 30 to 60
Unit Dimension (L*W*H) cm 75*26*55 93*28*55 100*30*62
Net Weight kg 40 48 59

* At condition of ambient temperature 20°C, water heated from 15°C to 55°C, average calculation results, according to our testing method.
** Power consumption of water pump has been included.

***Due to product improvement, subject to be changed without prior notice, please refer to the nameplate of the product as standard. 

NAT Series - Commercial models

NAT Series is a powerful edition. It delivers hot water for large hot water demand in hotels, resorts, clubs, schools, villa, sauna, and SPA, etc, as a trend of cost-effective water heating solution without pollution.

3_1_hpwh_c
Aseair Heat Pump Model:
AWH-010UYC, AWH-018UYC, AWH-023UYC, AWH-025UYC,
AWH-036UYC, AWH-045UYC, AWH-070UYC, AWH-090UYC
Model AM10B AM18B AM23B AM25B AM36B AM45B AM70B AM90B
Heating Power * kW 10 18 21.5 23 36 45 70 90
Rated Input Power * kW 2.63 4.5 5 9 9.4 11.25 15.4 19.4
Power Supply V/N~/Hz 380/3/50
Refrigerant / R407c/R410a
Applicable Ambient Temperature °C -5 to +43
Hot Water Production Volume * Ltrs/hour 210 380 490 774 925 968 1527 1935
Rated Water Outlet Temperature °C 55
Range of Water Outlet Temperature °C 30 to 58
Unit Dimension (L*W*H) cm 75*69*87 75*69*107 75*69*127 150*69*127 150*69*107 150*69*137 210*110*203 210*110*203
Net Weight kg 110 130 150 235 240 265 700 800

* At condition of ambient temperature 20°C, water heated from 15°C to 55°C, average calculation results, according to our testing method.
** Due to product improvement, subject to be changed without prior notice, please refer to the nameplate of the product as standard. 

Hot Water System-Pipeline Connection Schema

NATS4 Series - Commercial models

NATS4 Series is economic edition. It delivers hot water for large hot water demand in hotel, resort, club, school, valla, sauna and SPA etc, as a trend of cost-effective water heating solution without pollution.

AM054BS4

nats4_15p

AM072BS4

nats4_20p

AM090BS4

nats4_25p

AM108BS4

nats4_30p
Model AM054BS4 AM072BS4 AM090BS4 AM108BS4
Function / Heating/Auto defrost
Standard heating capacity kW 54 72 90 108
Standard input Power kW 13.8 17.1 21 25.4
Range of outlet water temperature °C 30 to 60
Maximum outlet water temperautre °C 58
Standard outlet water temperature °C 55
Working ambient air temperature °C -5 to +43
Type of compressor / Scroll
Compressor / Copeland
Quantity of compressor pcs 2 4 4 4
Type of fan motor Axial type
Quantity of fan motor pcs 2 2 2 3
Condensor (water heat exchanger) / Tube-in-shell type
Applicable to / Clean water
Water connections size inch/DN DN40 DN50 DN50 DN65
Evaporoator (air heat exchanger) / Aluminum fin-tube type
Expansion / EEV
Refrigerant / R407c/R410a
Controller type / Digital type
Unit dimension mm 1480*900*1550 1700*1100*1690 2000*1100*1890 2300*1100*1960
Packing dimension mm 1600*1000*1670 (approx.) 1880*1200*1870 (approx.) 2180*1200*2070 (approx.) 2420*1200*2140 (approx.)
Gross Weight kg 400 (approx.) 620 (approx.) 760 (approx.) 900 (approx.)

* At condition of ambient temperature 20°C, water heated from 15°C to 55°C, average calculation results, according to our testing method.
** Due to product improvement, subject to be changed without prior notice, please refer to the nameplate of the product as standard. 

Site icon_general energy co ltd_logo_draft

The renewable energy products for customers among the world.

Product

  • Heat Pump Water Heater

  • DC Inverter Heat Pump

  • Geothermal Heat Pump

  • Pool Heat Pump

  • Hot Water Buffer Tank

  • Accessories

Resources

  • FAQ

  • Articles

  • Videos

  • Useful Links

Company

  • About

  • News

  • Contact

  • Sitemap

  • Private Policy

General Energy Co., Ltd.

  • No.1, Yongtong Rd., Daliang, Shunde, Foshan, Guangdong, 528300, China

  • +86 137 9OO9 1175

Scroll to Top